Skip navigation

Delano

Local Reviews
for Delano, MN

Comfort Matters Rated 5.0 out of 5 stars based on 46 customer reviews

Our Reviews by City

Mound, MN (48)
Osseo, MN (251)
Otsego, MN (163)
Rogers, MN (407)


Map of Delano, MN

Excellent Service!




Review of Comfort Matters

Today I had a new furnace; air conditioner; air ducts cleaned and water heater installed and the experience was beyond exceptional! Installation went smoothly, everything was left clean and the customer service I received was amazing. Everyone installing the various systems were extremely friendly and went above and beyond to explain the process as well as the care and maintenance. The overall experience was a 10 out of 10!


Map of Delano, MN

Great Service!




Review of Comfort Matters

Nathan was very respectable in my home. He communicated clearly so I could understand what he was explaining to me. He provided an excellent service tune-up on my furnace. You are lucky to have him as a part of your team!


Map of Delano, MN

Great service!




Review of Comfort Matters

Anthony is always on time and makes sure everything is done and explained well before he leaves.


Map of Delano, MN

Great service!




Review of Comfort Matters

Anthony arrived right on time was very pleasant. He was also thorough and informative while doing our recent furnace service.


Map of Delano, MN

Great




Review of Comfort Matters


Map of Delano, MN

Comfort Matters never disappoints




Review of Comfort Matters

We have been customers for a number of years now and are always very happy with the technicians that take good care of our furnace and central air - Thank you all!


Map of Delano, MN

Great service




Review of Comfort Matters

Anthony was very knowledgeable and friendly.


Map of Delano, MN

Great service




Review of Comfort Matters

John is fantastic!! He has kept things up and running and is very informative.


Map of Delano, MN

Service was great. A little expensive




Review of Comfort Matters

Team was courteous and efficient. Did a great job. Very customer oriented


Map of Delano, MN

Love you guys!




Review of Comfort Matters


Quick and easy!




Review of Comfort Matters

Comfort Matters is great to work with. They call and schedule, guys show up and are friendly, they get the work done and it's over. Easy.


Great, fast service!




Review of Comfort Matters

The technician was early(which was great) and did a great job.


Tony does great work




Review of Comfort Matters

Friendly, fast, and knowledgeable.


Tony is very friendly. He was early which worked out great for me!




Review of Comfort Matters


Awesome service and Wes is your best Tech!




Review of Comfort Matters

Wes really knows his stuff and always take time to explain everything in detail. Fabulous customer service!!!


Always professional.




Review of Comfort Matters

Excellent work. Wes is very knowledgeable


Always great service




Review of Comfort Matters

Professional and efficient


Friendly and thorough as usual




Review of Comfort Matters


Helpful, friendly service!




Review of Comfort Matters


You guys are great!




Review of Comfort Matters

Nick did a great job.


Cody L.

Cody L.

Newer condenser unit was hit with forklift. This punctured condenser coils and blew refigerant charge. Evaluated and determined this is not repairable due to location of damage and size of puncture. New condenser unit quote attached with email, along with bill for diagnostics charge.

Near 7th St S, Delano, MN 55328
Derek B.

Derek B.

Customer informed me that ac and furnace were not running. I then inspected thermostat. Thermostat was functioning. Tested transformer on control board. Tested control board fuse. Tested power switch to the furnace. Power switch was failing. Customer agreed to replace switch. I replaced with new switch and tested operation. Ac and furnace now functioning properly. Recommended new evaporator coil drain line to prevent clogged drain line and water damage to furnace.

Near Greenway Dr, Delano, MN 55328
Corey H.

Corey H.

20 year old power vent water heater lost hot water last Tuesday. Customer unplugged the unit and plugged it back in, and has worked ever since. I cycled he unit on and off and it is working fine. There is a crack on a piece of plastic since it was installed that is not affecting the unit. Gave options for replacement. Customer wants to wait for water heater failure before making a decision.

Near Edmonson Ave SE, Delano, MN 55328
Anthony G.

Anthony G.

Ac was not operating upon arrival. After further diagnostics I found that the low voltage wiring within the furnace that controlled the air conditioner was no longer attached to the control board. I then reconfigured the wires and attached the their proper positions. Then turned the system back on. As of now everything is up and working. The outdoor unit is very dirty and I do highly recommend having a tuneup performed so we can get the system up and operating to its best ability and further check on how it is running. Also do recommend to at least start thinking about replacing the system due to age and to avoid any costly repairs needed.

Near Woods Creek Dr, Delano, MN 55328
Lucas N.

Lucas N.

Customer said she heard dripping in the basement and wanted to make sure the water heater wasn’t leaking. I checked all my fittings and none were leaking. I noticed condensation on several pipes near the water heater. The customer also said her toilet hasn’t stopped running since we installed her water heater. I spoke with Jake and he believes sediment from the galvanized pipe clogged the valve on the toilet causing it to remain open. The office is scheduled to call her around noon today to speak more about that.

Near 4th St S, Delano, MN 55328
Lucas N.

Lucas N.

Install 50 gallon electric water heater with new water valve. Cap venting and gas line. Electrical to be done by others.

Near 4th St S, Delano, MN 55328
Corey H.

Corey H.

No hot water because gas water heater became submerged in water due to dirt basement flooding. Customer has a pump inside a 5 gallon bucket with holes in it that isn’t working properly, and is connected to a garden hose. Water heater venting is not code and would need a liner installed. Gas valve not code. No water shut off to water heater. Galvanized piping inside home. Customer is getting an estimate to have the electrical connected to a water heater we install to get the water heater to code. Home has no block foundation, drain tile, or sump pit. Sump pump isn’t working consistently. Kay wants the friend that installed the pump to replace it again because drain tile and doing the job properly is too much of an investment. Home is from 1890.

Near 4th St S, Delano, MN 55328
Cody L.

Cody L.

Jake will be coming out Monday to assess plumbing in home. Basement is still flooded and water heater will not re light. Most likely when flooding occurred, components were damaged.

Near 4th St S, Delano, MN 55328
Anthony G.

Anthony G.

Water heater pilot light was out upon arrival. After reigniting the water heater I then adjusted the temperature up and the water heater started up right away. I let the water heater run for 5-10 minutes and the flames stayed on the whole time. The basement at the time was flooded and customer stated the basement has been flooded for the past couple days since the last rain storm. I do believe this is what caused the pilot light to go out. I highly recommend looking into seeing if a sump pump is applicable to this house.

Near 4th St S, Delano, MN 55328
Taylor L.

Taylor L.

Replace furnace and air conditioner with 96% AFUE 1-Stage Multi-Speed Furnace and 13 SEER A/C. Terms: 50% down, balance due at completion of installation OR Approved Financing

Near Merriman Dr, Delano, MN 55328
Nathan Y.

Nathan Y.

Furnace precision tune up; clean and tune up furnace; clean burners, test ignition components, adjust gas level, test safety circuit, check indoor motors, checked all electrical components, tested indoor air flow, checked heating temperatures, and tested overall furnace operation. Recommended whole system surge protector. Customer declined recommendation at this time.

Near Bonita Cir, Delano, MN 55328
Anthony G.

Anthony G.

Boiler precision tune up; clean and tune up boiler; check/verify water pressure, inspect burners, test ignition components, test/adjust gas level, test safety circuit, check motors and pumps, checked all electrical components, checked heating temperatures, test combustion, and tested overall boiler operation.

Near 4th St S, Delano, MN 55328
Anthony G.

Anthony G.

Water heater was operating upon arrival. After further diagnostics I found that the wright Hennepin electrical box had a Contactor that was severely burnt up and was humming loudly, customer noted that this component was even louder some times. I did notice that the contactor would get stuck down at certain times, I recommended having wright Hennepin come out and take a look to verify that their equipment is up and operating the way it should.

Near 95th St SE, Delano, MN 55328
Anthony G.

Anthony G.

Furnace precision tune up; clean and tune up furnace; clean burners, test ignition components, adjust gas level, test safety circuit, check indoor motors, checked all electrical components, tested indoor air flow, checked heating temperatures, and tested overall furnace operation. Added vent protection to the furnace exhaust and fresh air intake to help prevent any birds or other rodents from getting into the venting.

Near 4th St S, Delano, MN 55328
Anthony G.

Anthony G.

Furnace precision tune up; clean and tune up furnace; clean burners, test ignition components, adjust gas level, test safety circuit, check indoor motors, checked all electrical components, tested indoor air flow, checked heating temperatures, and tested overall furnace operation. Removed and replaced the water heater anode rod. After I installed the new one I turned the water heater back on and tested operation.

Near Vixen Ln, Delano, MN 55328
Anthony G.

Anthony G.

Furnace precision tune up; clean and tune up furnace; clean burners, test ignition components, adjust gas level, test safety circuit, check indoor motors, checked all electrical components, tested indoor air flow, checked heating temperatures, and tested overall furnace operation.

Near 44th St SE, Delano, MN 55328
Ian H.

Ian H.

Upon arrival the humidifier drain line was almost completely backed up to the top of the drain line. It was also noticed that the water line going to the solenoid was loose. The brass fitting was tightened and the drain line was replaced. After repairs were made, the operation of the humidifier was tested and there were no leaks present.

Near Krause Ave W, Delano, MN 55328
Daniel L.

Daniel L.

When arrived furnace would go through entire operation but would fail to ignite. Found the furnace to flash a 7 flash code looked it up and it said failed ignition. Tested the main igniter on the furnace and found it to not test. Replaced main igniter and tested operation of furnace. Also performed a Furnace precision tune up; clean and tune up furnace; clean burners, test ignition components, adjust gas level, test safety circuit, check indoor motors, checked all electrical components, tested indoor air flow, checked heating temperatures, and tested overall furnace operation. With the age of system would consider replacement in the future.

Near Kings Pointe Dr, Delano, MN 55328
John R.

John R.

Bar furnace working upon arrival. After going through all parts of furnace, found flame safety testing at 0. Installed a new part and turned power back on. Furnace is now working properly. Second furnace had pressure switch fault code upon arrival. Both pressure switches would not close. Was getting correct pressure to switch’s . Found a condensate line blocked going to condensate trap. Cleared it out. Furnace is working at this point, I do believe that the pressure switches are failing. Customer would like to hold of on new pressure switches for now. System replacement is recommended.

Near River St N, Delano, MN 55328
Cody L.

Cody L.

Annual Furnace precision tune up; clean and tune up furnace; clean burners, test ignition components, adjust gas level, test safety circuit, check indoor motors, checked all electrical components, tested indoor air flow, checked heating temperatures, and tested overall furnace operation. Furnace is operating normal at this time with no further concerns.

Near Brighton Ave SE, Delano, MN 55328
Anthony G.

Anthony G.

Boiler was not operating upon arrival. After further diagnostics I found that the system was low on water, first thing I did was filled the system back up to the proper operating pressures. I then reached out to the manufacture and went through basic diagnostics and found that the boiler is operating fine, although the system is being held back by the old oil fired boiler. I removed the oil boiler thermostat and found that the standard electric boiler is now up and working just fine. Overall I do recommend having someone come out that specializes in oil fired boilers just to ensure that everything is up and working just fine.

Near 95th St SE, Delano, MN 55328
Anthony G.

Anthony G.

Furnace precision tune up; clean and tune up furnace; clean burners, test ignition components, adjust gas level, test safety circuit, check indoor motors, checked all electrical components, tested indoor air flow, checked heating temperatures, and tested overall furnace operation. X2 Furnace for the brewery was off upon arrival. After further diagnostics I found that the blower motor bracket had completely snapped. I ordered the original motor and mounting bracket and replaced both of these components. After the repair was complete I tested operation and found that everything is now up and working properly again.

Near River St N, Delano, MN 55328
Anthony G.

Anthony G.

Return visit to install a new control board for the boiler. After installing the new control board I tested operation with the system and spoke with the manufacture to make sure everything is up and working properly. As of now lol zone and thermostats and also the boiler are up and working properly. I would continue to monitor the boiler over the next couple days and make sure that everything is still working just fine. If the renter has any questions about the thermostat please give us a call and I can reach back out, I did leave the manuals on the kitchen table.

Near Kelsey St, Delano, MN 55328
John R.

John R.

Installed customer supplied nest thermostat. Wired all connections correctly at thermostat and furnace. Got thermostat hooked up to WiFi and is now set up to be compatible to cell phone. Everything on furnace looks good. Filter was plugged. It would be recommended to use a 16x25x1 non pleated filter, generally a merv 1 or 2. Also Is generally see through. Would also recommend a whole home humidifier, this way there won’t be issues with filter getting so plugged so quick.

Near 2nd St S, Delano, MN 55328
Anthony G.

Anthony G.

Boiler was not operating upon arrival. Control board was flashing an error code relating to the ignition system. I tested the flame safety and found that I was not receiving any voltage from this component. In order to get the system up and operating properly we would have to replace the ignition system first and then test the boiler from there. Will follow up tomorrow morning on parts and pricing. Heaters were left with the customer until a repair can be made.